ZSSV-T Pneumatic segment regulating ball valve
ZSSV-TS Pneumatic segment regulating ball valve
ZSSV-TT series pneumatic valve V-regulation
ZSSV - TST series
ZSSV-TF Series
ZSSV-TM Series
ZSSV-E Pneumatic segment cutting ball valve
ZSSV-ES Series
ZSSV-ET Series
ZSSV-EST Series
ZSSR-T Pneumatic regulating ball valve
ZSSR-TS Pneumatic regulating ball valve
ZSSR-TT Series
ZSSR-TST Series
ZSSR-TF Series
ZSSR-TM Series
ZSSR-TCL Series
ZSSR-E Pneumatic cutting ball valve
ZSSR-ES Pneumatic cutting ball valve
ZSSR-ET Series
ZSSR-EST Series
ZSSW-T Series
ZSSW-TS Series
ZSSW-E Pneumatic cutting butterfly valve
ZSSW-ES Pneumatic cutting butterfly valve
ZSHQR-E Series
ZSHQR-T Series
ZSHFJ-E Series
ZKRV-T Series
ZKRV-E Series
ZKRR-T Series
ZKRR-E Electronical cutting ball valve
ZKRW-T Series
ZKRW-E Series
ZKRQR-ET Series
ZKRQR-T Series
ZDZV - 16T electric intelligent quantitative control valves
ZSLDC Pneumatic cutting knife gate valve
ZSLDSA Pneumatic cutting knife gate valve
ZSLDSB Pneumatic cutting knife gate valve
ZJHP(ZJHM) Series
ZKL (MP0) Series
ZSSR - 25EG Series
ZSSJR - E Series
ZKRJR - E series
MPSV - 2000 type manual slurry
PPSV - 2000 type pneumatic slurry
PPSV - 2000 type pneumatic slurry
MS-2000 Series
Slag discharge program controller
ZSHY(C)ZKRY(C)
PRODUCTS

Product name: ZSSV - T series pneumatic v-type regulating ball valve product model:
Product description:


Ⅰ Summary

ZSSV-T series pneumatic V-type hard seat regulating ball valve consists of double action actuator, V-type ball valve, and valve’s positioner and so on. It is received the control signal (4-20mA) from DCS, QCS, PLC and regulating instrument, which compare to the feedback from positioner. The outputting air pressure signal from positioner would operate the piston inner the cylinder of actuator. Then, turn the valve trim of V-type valve until the signal being pro data. The changes from the valve trim will change the sectional area of valve’s flowing to up to the purpose for regulating. Because it is following the   V-type trim, which has better sealing and cutting function. It is used for process controlling in the lots of industry areas, such as pulp paper, food, medicament, metallurgy, petroleum and chemistry, electric power ,sewage disposal industries and so on, especially for the medium of high viscosity and with fiber and small grain.

Ⅱ Main parameters and performance
◆Nominal pressure: 1.6Mpa 2.5Mpa4.0Mpa
◆Working temperature: 0℃-300℃
◆Leakage: GB/T17213-2005 class Ⅳ
◆Flow characteristic: Equal percentage Graph
◆Air-supply pressure :0.4 Mpa ~ 0.6 Mpa
◆Intrinsic error:1.0% ~2.0%
  Hysteresis plus dead band :1.0%~2.0%
  0.6%~0.8%
(Note: The above date are determined by the positioner)
◆Input signal: 0~10mADC 4~20mADC
◆Consumption of air: It mainly depends on the type of electric valve positioner selected. The air consumption of most positioner is 15L/min at home and abroad at present (air-supply pressure: 0.4Mpa), If select intellectual type, it will be less.

Ⅲ The compiling specification of series products’ model

 

Item
1
2
3
4
 
5
6
7
8
9
10
11
12
13
Explain
Z
S
 
V
 
 
 
 
 
 
 
 
 
1
Z
 
 
 
 
 
 
 
 
 
 
 
 
 
Final controlling element symbol
2
 
S
 
 
 
 
 
 
 
 
 
 
 
 
Pneumatic piston actuator
3
Cylinder maintenance type
S
 
 
 
 
 
 
 
 
 
 
 
Cylinder set upright
4
Plug structure
V
 
 
 
 
 
 
 
 
 
V~type
5
Nominal pressure
16
 
 
 
 
 
 
 
 
1.6Mpa
25
 
 
 
 
 
 
 
 
2.5Mpa
40
 
 
 
 
 
 
 
 
4.0Mpa
6
Control type
T
 
 
 
 
 
 
 
Regulating type
7
Action type
B
 
 
 
 
 
 
Air to close
K
 
 
 
 
 
 
Air to open
8
Nominal diameter DN(mm)
 
15
500
 
 
 
 
 
15、20、25、32、40、50、65、80、100、125、150、200、250、300、350、400、450、500
 
 
 
 
 
 
 
 
 
 
9
Seat type
 
Y
 
 
 
 
Self-adjusting hard seat
 
 
10
 
 
 
 
Valve body material
 
 
P
 
 
 
CF8
M
 
 
 
CF8M
L
 
 
 
CF3M
 
11
Input signal
D2
 
 
4-20mADC
 
 
12
 
 
 
 
Position limit switch
 
 
A
 
contact switch
B
 
Induction contactless switch 24VDC line two is made
C
 
Induction contactless switch 220VAC line two is made
13
Name of manufacture
LP
Zhejiang Tongpu automatic control equipment CO., Ltd.
(Wenzhou Lipu automatic control equipment CO., Ltd.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ⅳ Ordering demands
1.When to make the order; please choose the correct model referring to the item Ⅲ in the table. If not, you ’d better provide the   following information, such as the type, pressure, dimension, seal type, the main material, medium temperature, the inputting signal   from positioner (4-20MA).
2.The action type is formally air to open. If not, you could note it, including the special demands, such as in the anti-explosion area.
3.The choosing accessories;
    Limit switches:
   1) Contacted switches
   2) Induction switches (24VDC/220VAC) 
   The material of connecting flanges;
    A.A3 (Carbon steel)
    B.304SS
   3) The choosing positioners’ type;
    A. SVP-2000A from Jilin Haike CO.
    B. NELES 700 series or ND9100H series from METSO Company
    C. TZID-C series from ABB Company
    D. SIPART PS2 series from SIMENS Company
    E. YTC series (YT-1000R) from BELLOFRAM Company.
    F. PE400 series from SOMAS Company
    G. EP2400 series from HONEYWELL Company
    H. DVC6000 series from FISHER Company
    I. CHX series from Changshu Huaxia Company
    J. AVP3000 series from YAMATAKE Company  
4.If the valve would be used in the anti-explosion area, please note it while you make the inquiry. 
5.If the material of the seat is soft seat, you should note it because the common seat is metal seat.
 

Ⅴ Safety
ⅰ We make sure all the valves is very safe only if the material and pressure accord with the requirements in your order.
ⅱ According to the 4th part in the national standard(GB/T17213-2005/IEC60534-1999) of control valves industry area, it is the    examination and testing on duty. We have test and examined the pressure and material following the testing report so that we are sure    the safety of valves. The technical demands as followed,
1.Material testing
The physical test and chemical composition of the material for producing control valves accord with the standard of control valve or   the concerned requirements in the order.
2.the static pressure testing in the liquid
All the compositions of control valve, even no actuator, which must be finished the static testing in the liquid according to the   concerned pressure. i.e. it is tested by 1.5 times to the rating pressure.
 
Ⅵ  Principle of operation
The V-type regulating ball valve is made up of pneumatic actuator, valve body, and valve’s positioner, air filter, connecting and fastening pieces and so on. It finishes the position controlling from full open to full close by the valve’s positioner. Then, the signal (e.g., 0-10Ma, 4-20Ma,20-100K) from the controlling instrument or manual tool operating will control the valve’s positioner, which output the signal of air pressure at once to impulse the actuator so that it finishes the position controlling from open to closed by the wheel box to drive the V-type valve trim. The changes of valve’s position make the area of flowing changed so that it is up to the purpose for controlling flowing.
 
Ⅶ Installing, usage and maintenance
◆The position of installing the ball valve would be in the place as standing by the building platform 、a walking block ect. in order     to having the best watching、adjusting、Operating、maintenance and repairing. 
◆The pneumatic V- type ball valve may horizontal fix or vertical installing. 
◆When to install the valve body, the medium must be flow to in a direction from the arrows on the valve body. The control voltage is     either 24VDC or 220VAC.
◆You would be added to lube oil in the wheel box of the actuator and the joints for half year at least. 
◆The waste materials should be removed before installation of piping systems. Once installed, the position of the valve body must be     opened completely to sweep by blowing the wind into a pipeline. 
◆There are two screws(M12 ~ M20)  on the upper end of the cylinder of the pneumatic actuator and the lower end of the box, which is     used for adjusting the position from fully open to fully close.

Ⅷ Storage
Control valve had better be kept in the room among 5℃-40℃ temp. and ≤90% in the humidity. You’d better make sure there are no corrosive characteristics and other bad components in the air.
 
Ⅸ Packing and transportation
The packing material must accord with the concerned packing standard and demands. The packing must be intact and whole. It should have the own symbol against rain or dust and how to lay up. You should prevent the strong shaking in order to protecting the packing well in the journey of transportation.
 

X、ZSSV-T pneumatic segment regulating ball valve (double acting & wafer connecting)

 

 

1.Segment                                 2.Seat                                3.Shaft seal                                4.Box        

5.Frame                                      6.Nut                               7.Compression ring                     8.Cylinder lid 
9.Shaft                                        10.Bearing                      11.Bady                                         12.Lock spring  
13.O-type seal ring                  14.Positioner frame      15.Positioner                                16.Lower shaft  
17.Lower shift bearing            18.End plate seal          19.End plate                                 20.End plate screw
21.Positioner return shift         22.Lid                              23.Needle                                     24.O-type seal ring
25.Bearing                                 26.Axle                            27.Joint cross bolt                       28.Limited bolt   
29.Nut                                         30.Joint                           31.Rod                                          32.Road spring block ring
33.Air joint nu                            34.Air joint body           35.Air filter regulater                   36.Piston rod bolt 
37.Position bolt washer          38.Limited bolt              39.Nut                                            40.Double ended screw
41.Nut                                        42.Cylinder                     43.Y-type piston ring                  44.Gallow circle 
45.Piston rod                           46.Cylinder seal cushion 47.Cylinder brace lid 
 

 

Nominal
Size
DN
Flow
Quotiety
(Kv)
Dimension
Flange:GB/T9119-2000
A
L
H
X
Valve
N·W
(Kgs)
D
C
K
E
n-1
Flange
N·W
(kgs)
series:1
series:2
20
20
50
360
410
50
10.4
105
16
75
27.5
26
4-14
0.85
25
25
50
360
410
50
10.45
115
16
85
34.5
33
4-14
0.96
32
45
60
360
450
50
11.25
140
18
100
43.5
39
4-18
1.59
40
63
60
440
480
80
15.05
150
18
110
49.5
46
4-18
1.82
50
90
75
440
500
80
16.2
165
20
125
61.5
59
4-18
2.43
65
160
85
440
520
80
16.3
185
20
145
77.5
78
4-18
2.97
80
250
100
440
560
80
19.55
200
20
160
90.5
91
8-18
3.23
100
420
115
470
590
100
27.75
220
22
180
116
110
8-18
4.52
125
630
135
470
640
100
33.7
250
22
210
141.5
135
8-18
4.93
150
900
160
520
700
125
48.70
285
24
240
170.5
161
8-22
6.53

 

 

 

 

 

 

 



 

 

 

HOMEABOUTSPRODUCTSTECHNOLOGYNEWSDOWNLOADCONTACTS
Copyright(C) WenzhouShi Lipu Auto Control Equipment Co.,Ltd. All Rights Reserved. ADD:NO.125.Kangquan RD.Lucheng Ind.A.rea Wenzhou.Zhejian,China
Zip code:325000 TEL:0577-88608601 0577-88608605 M.P:13906651052 FAX:0577-88608602
E-mail:wzlipu@163.com http://www.wzlipu.com support:lianke.cn